Table of Contents
Introduction
This tutorial guides you through the process of commissioning a SINAMICS G120 drive using the Startdrive add-on in TIA Portal. By following these steps, you will be able to quickly set up and test the drive, making it easier to integrate into your automation projects. This process is essential for ensuring your drive operates correctly within your system.
Step 1: Install TIA Portal and Startdrive
- Ensure that you have TIA Portal installed on your computer.
- Download and install the Startdrive add-on if it is not already included in your TIA Portal installation.
- Open TIA Portal and verify that the Startdrive option is available in the menu.
Step 2: Create a New Project
- Open TIA Portal and select "Create new project."
- Name your project and choose an appropriate location to save it.
- Click "Create" to initialize your new project.
Step 3: Add SINAMICS G120 to the Project
- In the project tree, right-click on "Devices & Networks."
- Select "Add new device."
- Navigate to the "SINAMICS" section and choose "SINAMICS G120."
- Click "Add" to include the drive in your project.
Step 4: Configure the SINAMICS G120
- Double-click on the SINAMICS G120 device in the project tree to open its properties.
- Set the parameters according to your application needs, such as motor type, power rating, and other specific settings.
- Use the "Commissioning Wizard" in Startdrive to simplify this process.
Step 5: Use the Commissioning Wizard
- In the device properties, locate the "Commissioning" tab and select "Start Commissioning Wizard."
- Follow the on-screen instructions to input necessary parameters, such as:
- Motor parameters
- Control mode
- Feedback devices
- Make sure to review each step and verify the settings before proceeding.
Step 6: Perform a Test Run
- Once commissioning is complete, navigate to the "Startup" tab.
- Enable the drive and initiate a test run.
- Observe the drive’s behavior to ensure it operates as expected.
- Check for any alarms or faults and troubleshoot if necessary.
Step 7: Save and Document Your Configuration
- After successful testing, save the project configuration.
- Document key parameters and settings for future reference or for other team members.
Conclusion
You have now successfully commissioned a SINAMICS G120 drive using Startdrive in TIA Portal. This process not only streamlines the integration of the drive into your automation project but also ensures that it operates correctly. For future projects, remember to refer back to these steps, and don't hesitate to seek additional support if needed.