Lengkap! Cara Pasang Fast Connector Anti Gagal TARMOC "Fascon Joss"
Table of Contents
Introduction
This tutorial provides a comprehensive guide on installing the TARMOC Fast Connector, specifically the TCN-SC/U-FHG model. Designed to ensure minimal signal loss (≤ 0.3dB) when correctly installed, this connector is ideal for fiber optic cable connections. Follow these steps to achieve a successful installation.
Step 1: Gather Necessary Tools and Materials
Before starting the installation, ensure you have all the required tools and materials. This will help streamline the process and prevent interruptions.
- TARMOC Fast Connector TCN-SC/U-FHG
- Fiber optic cable
- Fiber optic stripping tool
- Cleaver tool
- Optical power meter (for testing)
- Safety goggles
- Cleaning wipes
Step 2: Prepare the Fiber Optic Cable
Proper preparation of the fiber optic cable is crucial for a successful connection.
- Measure the Length: Determine the length of fiber optic cable needed for your installation.
- Strip the Cable:
- Use the fiber optic stripping tool to carefully strip the outer jacket of the fiber optic cable.
- Remove approximately 3-4 cm of the jacket, exposing the inner fibers.
- Strip the Fiber:
- Strip the protective coating from the fiber itself, exposing about 1-2 cm of the glass fiber.
- Be cautious to avoid damaging the fiber.
Step 3: Cleave the Fiber
A clean cleave is essential for optimal performance.
- Use the Cleaver Tool: Place the stripped fiber in the cleaver.
- Follow Cleaving Instructions: Ensure you adhere to the manufacturer's instructions for the cleaver tool to achieve a clean cut.
- Inspect the Cut: Check that the end of the fiber is smooth and flat. Any imperfections can lead to signal loss.
Step 4: Assemble the Fast Connector
Now it’s time to connect the fiber to the Fast Connector.
- Insert the Fiber:
- Carefully insert the cleaved fiber into the fast connector.
- Ensure it reaches the end of the connector.
- Secure the Connector:
- Follow the specific instructions on securing the fiber within the connector.
- Ensure it is firmly held in place to avoid signal loss.
Step 5: Test the Connection
After installation, testing is crucial to confirm the connection works as intended.
- Use an Optical Power Meter:
- Connect the optical power meter to the opposite end of the cable.
- Measure the signal strength to ensure it meets the acceptable loss levels.
- Check for Signal Loss:
- Verify that the loss is ≤ 0.3dB.
- If the loss is higher, recheck the installation for any issues.
Conclusion
Successfully installing the TARMOC Fast Connector requires careful preparation, precise cleaving, and secure assembly. By following these steps, you can ensure a reliable fiber optic connection. For further improvements, consider watching related videos on fiber optic installations or exploring different types of connectors. Happy connecting!