Step-by-Step Tutorial: Repurposing a Data Center Server Cooler for Computer Water Cooling

  1. Introduction to the Cooler

    • In the YouTube video titled "I Can’t Believe They Threw This Away" by Linus Tech Tips, a data center server cooler is repurposed for computer water cooling.
  2. Inspecting the Cooler

    • Take a close look at the server cooler and note its unique features, such as insulation and condensation collection design.
  3. Understanding the Cooling Process

    • Understand how the cooler works by taking in hot air from servers, passing it through water to cool it down, and then blowing it back out to recycle into server racks.
  4. Preparing for Modifications

    • Gather necessary tools and materials for modifying the cooler, such as refrigeration components, tubing, and fans.
  5. Modifying the Cooler

    • Cut and solder copper pipes to create a cooling loop within the cooler.
    • Install G14 threaded endcap fittings to secure the tubing connections.
    • Ensure a secure and leak-free connection by soldering the joints properly.
  6. Installing Fans and Power Supply

    • Replace existing fans with high-performance fans to enhance cooling efficiency.
    • Connect a dedicated power supply to power the fans for optimal performance.
  7. Testing the Cooling System

    • Prime the pump and allow the system to circulate water through the cooler.
    • Monitor the system for leaks and ensure proper water flow through the cooling loop.
  8. Optimizing the Cooling System

    • Adjust fan speeds to achieve the desired cooling capacity.
    • Verify that the system can handle the heat generated by a high-power CPU by running stress tests.
  9. Monitoring Performance

    • Check CPU temperatures during operation to ensure efficient cooling.
    • Benchmark the system over an extended period to evaluate its cooling capabilities under load.
  10. Finalizing the Setup

    • Secure all connections and ensure the system is running smoothly.
    • Consider additional modifications or adjustments based on performance testing results.
  11. Conclusion

    • Appreciate the effectiveness of the repurposed data center cooler for computer water cooling.
    • Consider future upgrades or modifications to further enhance cooling performance.
  12. Optional Step: Cleaning Up

    • Use a robotic vacuum cleaner like the Roborock S8 Max V Ultra to clean up any mess created during the modification process.

By following these steps, you can effectively repurpose a data center server cooler for computer water cooling and optimize its performance for efficient cooling of high-power components.