To display the exact percentage of desired chlorine output:
-
Instant Salt Reading:
- Press the diagnostic button five times.
- Note that the value will show a negative sign; this indicates it’s the instant salt reading, not negative salt.
-
Reset Average Salt Reading:
- Move the selector switch from Auto to Super chlorinate and then back to Auto.
- Press the diagnostic button four times to return to the default screen.
- The average salt reading level will reset to 3,000 parts per million, which is now the current instant salt level.
Chapter 2: Changing the Desired Chlorine Output Percentage
To change the percentage of desired chlorine output:
-
Access Diagnostic Mode:
- Press the diagnostic button four times.
- Adjust the dial to see the value change as you adjust it.
-
Switching to Super Chlorinate:
- When you move the selector switch from Auto to Super chlorinate, the output immediately goes to 100%, regardless of the dial setting.
- The system will operate at 100% until you switch back to Auto, the pump shuts off, or 24 hours elapse.
Chapter 3: Configuring the AquaRite with Remote Control
To change the product name displayed on the remote control:
-
Access Remote Control Settings:
- Press the diagnostic button six times.
- Switch the selector from Auto to Super chlorinate and back to Auto.
-
Select Desired Setting:
- Repeat the process until the desired setting (from 1 to 5) is reached.
- Refer to the owner’s manual for details on available settings.
Chapter 4: Clearing the Inspect Cell Blinking LED
To clear the blinking LED that indicates you need to inspect the cell:
-
Diagnostic Access:
- Press the diagnostic button eight times.
- Move the selector switch from Auto to Super chlorinate and back to Auto.
-
Confirm T-Cell Type:
- Repeat this process until the correct T-cell type is displayed.
Chapter 5: Configuring US Measurements
To change the system from metric to US measurements:
-
Reset Inspect Cell Timer:
- When the inspect cell LED is blinking, it indicates a reminder to inspect the T-cell after 500 hours of operation.
- To reset this timer, press and hold the diagnostic button for 3 to 5 seconds until the light turns off.
-
Switch Measurement Units:
- Press the diagnostic button once to change from metric to US measurements.
- Move the selector switch from Auto to Super chlorinate and back to Auto to complete the change.
- For example, if the system reads 22° C, it will convert to 72° F after this process.
Conclusion
In this tutorial, you learned how to display and adjust the chlorine output percentage, configure settings with a remote control, clear the inspect cell LED, and switch between metric and US measurements. Regular maintenance and proper configuration of your AquaRite will help maintain optimal performance. For further details, always refer to your owner's manual and stay proactive with your pool maintenance.