Codesys to ControlLogix over Ethernet IP
2 min read
2 hours ago
Published on Feb 12, 2025
This response is partially generated with the help of AI. It may contain inaccuracies.
Table of Contents
Introduction
This tutorial provides a step-by-step guide on how to establish communication over EtherNet/IP between a Codesys PLC and a ControlLogix PLC. Understanding this process is essential for automation engineers looking to integrate different PLC systems effectively.
Step 1: Prepare Your Hardware
- Ensure that both the Codesys PLC and the ControlLogix PLC are powered on and connected to the same Ethernet network.
- Verify that your Ethernet/IP adapter is correctly configured and operational.
- Check the IP addresses assigned to both PLCs to ensure they are in the same subnet.
Step 2: Configure Codesys for EtherNet/IP
- Open the Codesys development environment.
- Navigate to the device tree and add a new EtherNet/IP device.
- Set the parameters for the EtherNet/IP adapter:
- Enter the IP address of the ControlLogix PLC.
- Set the port number to the default EtherNet/IP port (typically 44818).
- Define the necessary input and output assemblies as per your application requirements.
Step 3: Set Up ControlLogix for EtherNet/IP
- Launch the RSLogix 5000 or Studio 5000 software.
- Create a new project or open an existing one.
- Add the EtherNet/IP module to your ControlLogix system.
- Configure the module:
- Input and output sizes must match those defined in the Codesys configuration.
- Set the connection parameters, including the IP address of the Codesys PLC.
Step 4: Establish Communication
- In Codesys, create a network variable that corresponds to the ControlLogix variable.
- Use the appropriate function blocks to read from and write to the ControlLogix PLC:
- For reading data, you might use a function block like
EthernetIP_Read
. - For writing data, utilize
EthernetIP_Write
.
- For reading data, you might use a function block like
- Ensure that the data types match between the two systems to avoid communication errors.
Step 5: Testing the Connection
- Deploy the Codesys application to the PLC.
- Go to the ControlLogix PLC and monitor the data being received from Codesys.
- Use diagnostic tools in both environments to verify that data is being transmitted correctly.
Conclusion
By following these steps, you can successfully establish communication between a Codesys PLC and a ControlLogix PLC over EtherNet/IP. This setup allows for effective data exchange and integration in automation projects. As a next step, explore advanced communication strategies or consider implementing additional features such as error handling and logging for improved reliability.